Workshop overview
Chapter 2 of 7
15 min

Read sensor values together with quality signals

Read value, unit, and quality signal together across 216 sensor rows to separate four explicit high-risk signals from rows that cannot be used at all.

Question for this chapter

Which rows are alert candidates, and which cannot be used in the first place?

Why this matters now

A temperature of 103.7 and a vibration of 4.71 use different units and different normal ranges. Comparing raw magnitudes judges unlike sensors by one yardstick. Read value, unit, sensor_type, and quality_flag as one bundle.

A quality signal does two different jobs. It can report that a value left its normal range, or that the sensor cannot produce a value at all. Mixing the two mistakes a broken sensor for a failing machine.

Try it

Open the preview of machine_sensors (Machine Sensor Readings) in the processed collection. Sort so these columns are visible, then group by quality_flag.

machine_id, sensor_type, value, unit, recorded_at, quality_flag

What success looks like

The 216 rows break down like this.

quality_flagRowsMeaning
OK210Normal reading
HIGH_VIBRATION · HIGH_PRESSURE · HIGH_TEMP4High-risk condition reported by the source
OFFLINE2Sensor cannot produce a value

The four rows starting with HIGH_ are the starting point for this decision.

MachineSensorValueQuality signalRecorded
CNC-03vibration4.71 m/s²HIGH_VIBRATION03-01 08:00:30
CNC-05pressure8.9 barHIGH_PRESSURE03-01 08:01:00
CNC-09temperature103.7 °CHIGH_TEMP03-01 08:01:30
CNC-07temperature101.2 °CHIGH_TEMP03-02 08:00:00
Korean Portal showing the HIGH_VIBRATION quality signal for CNC-03 in machine sensor readings
The Portal capture is in Korean. Confirm the source HIGH quality signal alongside value, unit, and machine ID.

Interpret the result

These four rows are not inferred from magnitude. The sensor source already reported a condition, so the next chapter's statistical threshold must not override them.

The two OFFLINE rows are a different case. Both come from CNC-09's pressure sensor and their values are unremarkable at 5.4 and 5.3 bar. But the sensor reported itself as not operating normally, so the values cannot be trusted. The normalization step in the next chapter filters rows like these out.

Six rows have no value at all: two CNC-04 vibration rows and four CNC-08 pressure rows. Rather than discarding them, normalization carries the previous value forward — but it gives up when a gap runs too long.

Machine configuration is not evidence

There are 27 unique machine_id and sensor_type pairs. All nine machines carry the same three sensor types — vibration, temperature, and pressure — so configuration alone cannot say which machine is at risk. The judgment has to come from values and signals.

Next decision

You have separated the four alert candidates from the rows to filter out. Next, learn how a three-sigma check puts every value on one scale, and how explicit quality signals work alongside it. Which zone each machine sits in and who owns it comes from the ontology in chapter 5.